{"id":1468,"date":"2026-11-21T10:47:52","date_gmt":"2026-11-21T02:47:52","guid":{"rendered":"https:\/\/www.ypmfg.com\/2026\/11\/21\/how-to-prototype-a-medical-device\/"},"modified":"2026-11-21T10:47:52","modified_gmt":"2026-11-21T02:47:52","slug":"how-to-prototype-a-medical-device","status":"publish","type":"post","link":"https:\/\/www.ypmfg.com\/es\/2026\/11\/21\/how-to-prototype-a-medical-device\/","title":{"rendered":"How to Prototype a Medical Device"},"content":{"rendered":"<div style=\"margin: 0 auto;padding: 20px;font-family: -apple-system, BlinkMacSystemFont, &#039;Segoe UI&#039;, Roboto, &#039;Helvetica Neue&#039;, Arial, sans-serif\">\n<blockquote style=\"margin: 1.6em 0;padding: 1.2em 1.5em;background: linear-gradient(90deg, #faf2f4 0%, #fff 100%);border-left: 4px solid #d05570;color: #444444;font-style: italic;border-radius: 0 8px 8px 0\">\n<p style=\"margin: 1.25em 0;line-height: 1.9;font-size: 16px;color: #222222;text-align: justify;letter-spacing: 0.02em\">A medical device prototype must clear three gates: material traceability,biocompatibility screening, and <strong style=\"font-weight: 600;color: #b32050\">ISO 13485<\/strong>-aligned documentation. Skip any one and the design fails regulatory review before it ever reaches a user.<\/p>\n<\/blockquote>\n<p style=\"margin: 1.25em 0;line-height: 1.9;font-size: 16px;color: #222222;text-align: justify;letter-spacing: 0.02em\">Most medical device teams lose 6 to 8 weeks on prototype rework because the first build skips biocompatibility validation or tolerance stacking. The gap sits between <strong style=\"font-weight: 600;color: #b32050\">Mecanizado CNC<\/strong> tolerances and the actual load the part carries in vivo. YPMFG works with design teams to close that gap before the first cut is made. What follows walks through where prototypes fail and what to verify at each stage.<\/p>\n<p style=\"margin: 1.25em 0;line-height: 1.9;font-size: 16px;color: #222222;text-align: justify;letter-spacing: 0.02em\">\n<ul style=\"margin: 1.2em 0;padding-left: 1.8em;line-height: 1.9;list-style-type: disc\">\n<li style=\"margin: 0.5em 0;color: #222222\"><strong style=\"font-weight: 600;color: #b32050\">Trazabilidad de los materiales<\/strong>: Every lot needs an ASTM or ISO 13485 certificate; unbranded 316L stock fails a regulatory audit.<\/li>\n<li style=\"margin: 0.5em 0;color: #222222\"><strong style=\"font-weight: 600;color: #b32050\">Tolerance stacking<\/strong>: Three mating features at ISO 2768-m can drift past the 0.1 mm envelope on a sliding joint.<\/li>\n<li style=\"margin: 0.5em 0;color: #222222\"><strong style=\"font-weight: 600;color: #b32050\">Regulatory documentation<\/strong>: A prototype without a Design History Record cannot enter a 510(k) submission.<\/li>\n<p style=\"margin: 1.25em 0;line-height: 1.9;font-size: 16px;color: #222222;text-align: justify;letter-spacing: 0.02em\"><\/ul>\n<\/p>\n<h2 style=\"font-size: 20px;font-weight: 600;margin: 1.4em 0 0.5em;color: #b32050;line-height: 1.4\">What Makes Medical Device <a href=\"\/es\/2026\/10\/09\/cnc-machining-services-in-china-key-checks\/\" title=\"Creaci\u00f3n de prototipos\" target=\"_blank\">Creaci\u00f3n de prototipos<\/a> Different?<\/h2>\n<p style=\"margin: 1.25em 0;line-height: 1.9;font-size: 16px;color: #222222;text-align: justify;letter-spacing: 0.02em\">A medical device prototype is not a visual mockup. It must carry full material traceability and a documented design intent that an auditor can follow end to end.<\/p>\n<p style=\"margin: 1.25em 0;line-height: 1.9;font-size: 16px;color: #222222;text-align: justify;letter-spacing: 0.02em\">Standard CNC parts ship with a dimension report. A medical part ships with a <strong style=\"font-weight: 600;color: #b32050\">Design History Record<\/strong>, lot numbers tied to ASTM or ISO 13485 certificates, and <strong style=\"font-weight: 600;color: #b32050\">biocompatibility<\/strong> test data per ISO 10993-1. The machining process stays the same; the validation chain and paperwork are what separate the two workflows.<\/p>\n<p style=\"margin: 1.25em 0;line-height: 1.9;font-size: 16px;color: #222222;text-align: justify;letter-spacing: 0.02em\">\n<ul style=\"margin: 1.2em 0;padding-left: 1.8em;line-height: 1.9;list-style-type: disc\">\n<p style=\"margin: 1.25em 0;line-height: 1.9;font-size: 16px;color: #222222;text-align: justify;letter-spacing: 0.02em\"><img decoding=\"async\" src=\"https:\/\/www.ypmfg.com\/wp-content\/themes\/mb\/images_nengli\/stamping-optimized.png\" alt=\"medical device prototype development_medicaldevice_medical\u662f\u4ec0\u4e48\u610f\u601d\" style=\"width: 100%;max-width: 960px;height: auto;display: block;margin: 1.8em auto;border-radius: 0px\"><\/p>\n<li style=\"margin: 0.5em 0;color: #222222\">Material lot certificates: ASTM F899 for 316L, ASTM F136 for Ti-6Al-4V<\/li>\n<li style=\"margin: 0.5em 0;color: #222222\">Surface finish spec per <strong style=\"font-weight: 600;color: #b32050\">ISO 2768<\/strong> or ASME Y14.5<\/li>\n<li style=\"margin: 0.5em 0;color: #222222\">DFM notes from the design team on wall thickness and draft angles<\/li>\n<li style=\"margin: 0.5em 0;color: #222222\">Lot ID laser-marked on each part before deburr<\/li>\n<p style=\"margin: 1.25em 0;line-height: 1.9;font-size: 16px;color: #222222;text-align: justify;letter-spacing: 0.02em\"><\/ul>\n<\/p>\n<p style=\"margin: 1.25em 0;line-height: 1.9;font-size: 16px;color: #222222;text-align: justify;letter-spacing: 0.02em\">The next step is sending your BOM and tolerance stack-up to YPMFG for an engineering review before any material is cut.<\/p>\n<p style=\"margin: 1.25em 0;line-height: 1.9;font-size: 16px;color: #222222;text-align: justify;letter-spacing: 0.02em\">CNC holds \u00b10.02 mm on a flat surface, but micro-channels below 0.3 mm width often require LIGA or photo-etched processes instead.<\/p>\n<h2 style=\"font-size: 20px;font-weight: 600;margin: 1.4em 0 0.5em;color: #b32050;line-height: 1.4\">Which Materials Pass Regulatory Review?<\/h2>\n<p style=\"margin: 1.25em 0;line-height: 1.9;font-size: 16px;color: #222222;text-align: justify;letter-spacing: 0.02em\">Material choice gates everything downstream. The wrong alloy stalls FDA review no matter how tight your tolerances are.<\/p>\n<p style=\"margin: 1.25em 0;line-height: 1.9;font-size: 16px;color: #222222;text-align: justify;letter-spacing: 0.02em\">For implants and body-contact parts, 316L and Ti-6Al-4V dominate. 304 SS suits external housings. Thermoplastics such as medical-grade ABS and PC cover non-implant enclosures. Nylon 11 or 12 handles flexible gaskets and wear pads. The material must match the intended use class defined in your risk file.<\/p>\n<table style=\"width: 100%;border-collapse: collapse;margin: 1.6em 0;border-radius: 10px 10px 0 0;overflow: hidden\">\n<thead>\n<tr>\n<th style=\"background: #9e1840;color: #fff;padding: 14px 16px;text-align: left;font-weight: 600;border: 1px solid #e0e0e0\">Material<\/th>\n<th style=\"background: #9e1840;color: #fff;padding: 14px 16px;text-align: left;font-weight: 600;border: 1px solid #e0e0e0\">Uso habitual<\/th>\n<th style=\"background: #9e1840;color: #fff;padding: 14px 16px;text-align: left;font-weight: 600;border: 1px solid #e0e0e0\">Biocompliance<\/th>\n<th style=\"background: #9e1840;color: #fff;padding: 14px 16px;text-align: left;font-weight: 600;border: 1px solid #e0e0e0\">Limitaci\u00f3n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"padding: 12px 16px;color: #222222;border: 1px solid #e0e0e0\">316L<\/td>\n<td style=\"padding: 12px 16px;color: #222222;border: 1px solid #e0e0e0\">Implantes, instrumentos quir\u00fargicos<\/td>\n<td style=\"padding: 12px 16px;color: #222222;border: 1px solid #e0e0e0\">ISO 10993-5<\/td>\n<td style=\"padding: 12px 16px;color: #222222;border: 1px solid #e0e0e0\">Chloride pitting in saline<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 12px 16px;color: #222222;border: 1px solid #e0e0e0\">304 SS<\/td>\n<td style=\"padding: 12px 16px;color: #222222;border: 1px solid #e0e0e0\">External housings<\/td>\n<td style=\"padding: 12px 16px;color: #222222;border: 1px solid #e0e0e0\">ISO 10993-5<\/td>\n<td style=\"padding: 12px 16px;color: #222222;border: 1px solid #e0e0e0\">Not for implant contact<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 12px 16px;color: #222222;border: 1px solid #e0e0e0\">Medical ABS \/ PC<\/td>\n<td style=\"padding: 12px 16px;color: #222222;border: 1px solid #e0e0e0\">Tool handles, shells<\/td>\n<td style=\"padding: 12px 16px;color: #222222;border: 1px solid #e0e0e0\">ISO 10993-5\/10<\/td>\n<td style=\"padding: 12px 16px;color: #222222;border: 1px solid #e0e0e0\">Creep above 60 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 12px 16px;color: #222222;border: 1px solid #e0e0e0\">Nylon 11 \/ 12<\/td>\n<td style=\"padding: 12px 16px;color: #222222;border: 1px solid #e0e0e0\">Gaskets, flex joints<\/td>\n<td style=\"padding: 12px 16px;color: #222222;border: 1px solid #e0e0e0\">ISO 10993-5<\/td>\n<td style=\"padding: 12px 16px;color: #222222;border: 1px solid #e0e0e0\">Fatigue below 10\u2074 cycles<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"margin: 1.25em 0;line-height: 1.9;font-size: 16px;color: #222222;text-align: justify;letter-spacing: 0.02em\"><img decoding=\"async\" src=\"https:\/\/www.ypmfg.com\/wp-content\/themes\/mb\/images_nengli\/medical-devices-optimized.jpg\" alt=\"medicaldevice_medical\u662f\u4ec0\u4e48\u610f\u601d_medical device prototype development\" style=\"width: 100%;max-width: 960px;height: auto;display: block;margin: 1.8em auto;border-radius: 0px\"><\/p>\n<p style=\"margin: 1.25em 0;line-height: 1.9;font-size: 16px;color: #222222;text-align: justify;letter-spacing: 0.02em\">Always request the mill certificate and confirm the lot number matches your DHR before cutting. No single plastic replicates metal fatigue life; above a few thousand flex cycles, switch to a metal or composite.<\/p>\n<h2 style=\"font-size: 20px;font-weight: 600;margin: 1.4em 0 0.5em;color: #b32050;line-height: 1.4\">Where Do Prototypes Fail Before Production?<\/h2>\n<p style=\"margin: 1.25em 0;line-height: 1.9;font-size: 16px;color: #222222;text-align: justify;letter-spacing: 0.02em\">The top failure mode is <strong style=\"font-weight: 600;color: #b32050\">tolerance stacking<\/strong> across three or more mating features. Each part sits within spec, but the assembled unit drifts out of envelope.<\/p>\n<p style=\"margin: 1.25em 0;line-height: 1.9;font-size: 16px;color: #222222;text-align: justify;letter-spacing: 0.02em\">A 5-axis CNC part with 4 mating surfaces at ISO 2768-m accumulates worst-case error fast. Run a tolerance stack-up in CAD before ordering. Flag any assembled gap below 0.05 mm for a tighter machining route or a press-fit redesign.<\/p>\n<p style=\"margin: 1.25em 0;line-height: 1.9;font-size: 16px;color: #222222;text-align: justify;letter-spacing: 0.02em\">\n<ul style=\"margin: 1.2em 0;padding-left: 1.8em;line-height: 1.9;list-style-type: disc\">\n<li style=\"margin: 0.5em 0;color: #222222\">Gap &gt; 0.1 mm across 3 joints: relax spec or add a shim<\/li>\n<li style=\"margin: 0.5em 0;color: #222222\">Surface finish unspecified: default Ra is too rough for sliding joints<\/li>\n<li style=\"margin: 0.5em 0;color: #222222\">Wall thickness &lt; 0.5 mm on a molded part: add rib support in DFM<\/li>\n<li style=\"margin: 0.5em 0;color: #222222\">Material lot not matched to DHR: traceability break, re-quote required<\/li>\n<p style=\"margin: 1.25em 0;line-height: 1.9;font-size: 16px;color: #222222;text-align: justify;letter-spacing: 0.02em\"><\/ul>\n<\/p>\n<p style=\"margin: 1.25em 0;line-height: 1.9;font-size: 16px;color: #222222;text-align: justify;letter-spacing: 0.02em\">YPMFG can run a <strong style=\"font-weight: 600;color: #b32050\">Revisi\u00f3n DFM<\/strong> on your STEP file and flag risk features within 48 hours. No machining shop holds a 0.005 mm gap in a 12-feature assembly without a fixturing redesign; plan for a press-fit or snap-fit there.<\/p>\n<h2 style=\"font-size: 20px;font-weight: 600;margin: 1.4em 0 0.5em;color: #b32050;line-height: 1.4\">How a 3-Axis CNC Route Handles a Sliding-Joint Prototype<\/h2>\n<p style=\"margin: 1.25em 0;line-height: 1.9;font-size: 16px;color: #222222;text-align: justify;letter-spacing: 0.02em\">Typical sliding-joint prototypes (guide rails, actuator housings) follow a 3-axis CNC route on 316L or 304 stock. The sequence: rough mill \u2192 finish mill to \u00b10.02 mm \u2192 deburr \u2192 surface finish per ISO 2768 \u2192 dimensional report plus lot certificate.<\/p>\n<p style=\"margin: 1.25em 0;line-height: 1.9;font-size: 16px;color: #222222;text-align: justify;letter-spacing: 0.02em\">Key control points: fixturing flatness under 0.01 mm and tooling wear checks every 20 parts. The most common failure is an unmarked lot number traced to the wrong material batch. Prevention: laser-mark each part with its lot ID before the deburr step.<\/p>\n<blockquote style=\"margin: 1.6em 0;padding: 1.2em 1.5em;background: linear-gradient(90deg, #faf2f4 0%, #fff 100%);border-left: 4px solid #d05570;color: #444444;font-style: italic;border-radius: 0 8px 8px 0\">\n<p style=\"margin: 1.25em 0;line-height: 1.9;font-size: 16px;color: #222222;text-align: justify;letter-spacing: 0.02em\">Process Route Reference: YPMFG process library, reviewed against published tooling data. Client-specific data withheld per NDA.<\/p>\n<\/blockquote>\n<h2 style=\"font-size: 20px;font-weight: 600;margin: 1.4em 0 0.5em;color: #b32050;line-height: 1.4\">Common Questions Before You Order a Medical Device Prototype<\/h2>\n<p style=\"margin: 1.25em 0;line-height: 1.9;font-size: 16px;color: #222222;text-align: justify;letter-spacing: 0.02em\"><strong style=\"font-weight: 600;color: #b32050\">Can CNC hold a 0.01 mm tolerance on a medical part?<\/strong> No. Practical CNC floor sits near 0.02 mm on a stable setup. Below that you need grinding or lapping, which adds a separate process step and cost.<\/p>\n<p style=\"margin: 1.25em 0;line-height: 1.9;font-size: 16px;color: #222222;text-align: justify;letter-spacing: 0.02em\"><strong style=\"font-weight: 600;color: #b32050\">Do I need ISO 13485 from my prototyping shop?<\/strong> Only if the prototype feeds a 510(k) or MDR file. For internal design validation, a documented DHR and material certificates suffice. YPMFG can supply either level on request.<\/p>\n<p style=\"margin: 1.25em 0;line-height: 1.9;font-size: 16px;color: #222222;text-align: justify;letter-spacing: 0.02em\"><strong style=\"font-weight: 600;color: #b32050\">What is the fastest route from CAD to a biocompatible sample?<\/strong> Three-day 3-axis CNC on 316L stock, then ISO 10993-5 screening. Total turnaround is roughly 3 to 7 days plus 5 days for lab testing.<\/p>\n<h2 style=\"font-size: 20px;font-weight: 600;margin: 1.4em 0 0.5em;color: #b32050;line-height: 1.4\">Choosing the Right Prototype Path for Your Device<\/h2>\n<p style=\"margin: 1.25em 0;line-height: 1.9;font-size: 16px;color: #222222;text-align: justify;letter-spacing: 0.02em\">The right first build saves 6 weeks of rework. Send your STEP files, BOM, and tolerance stack-up to YPMFG for a free engineering review. The team flags DFM risks, material compliance gaps, and fixturing issues before any material is cut. You receive a written risk list and a recommended process route within 48 hours. From there, a three-day prototype lands on your desk with full traceability documentation and the ISO 13485-aligned records your next submission needs.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>A medical device prototype must clear three gates: material traceability<\/p>","protected":false},"author":1,"featured_media":1469,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[44],"tags":[202,406,1157,1158,1159],"class_list":["post-1468","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","tag-prototyping","tag-cnc-machining","tag-medical-device","tag-biocompatibility","tag-regulatory-compliance"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>How to Prototype a Medical Device<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.ypmfg.com\/es\/2026\/11\/21\/how-to-prototype-a-medical-device\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How to Prototype a Medical Device\" \/>\n<meta property=\"og:description\" content=\"A medical device prototype must clear three gates: material traceability\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.ypmfg.com\/es\/2026\/11\/21\/how-to-prototype-a-medical-device\/\" \/>\n<meta property=\"og:site_name\" content=\"YP-MFG| Custom CNC Parts Made Exactly to Spec\" \/>\n<meta property=\"article:published_time\" content=\"2026-11-21T02:47:52+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.ypmfg.com\/wp-content\/themes\/mb\/images_nengli\/stamping-optimized.png\" \/>\n<meta name=\"author\" content=\"admin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutos\" \/>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"How to Prototype a Medical Device","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.ypmfg.com\/es\/2026\/11\/21\/how-to-prototype-a-medical-device\/","og_locale":"es_ES","og_type":"article","og_title":"How to Prototype a Medical Device","og_description":"A medical device prototype must clear three gates: material traceability","og_url":"https:\/\/www.ypmfg.com\/es\/2026\/11\/21\/how-to-prototype-a-medical-device\/","og_site_name":"YP-MFG| Custom CNC Parts Made Exactly to Spec","article_published_time":"2026-11-21T02:47:52+00:00","og_image":[{"url":"https:\/\/www.ypmfg.com\/wp-content\/themes\/mb\/images_nengli\/stamping-optimized.png","type":"","width":"","height":""}],"author":"admin","twitter_card":"summary_large_image","twitter_misc":{"Escrito por":"admin","Tiempo de lectura":"4 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.ypmfg.com\/es\/2026\/11\/21\/how-to-prototype-a-medical-device\/#article","isPartOf":{"@id":"https:\/\/www.ypmfg.com\/es\/2026\/11\/21\/how-to-prototype-a-medical-device\/"},"author":{"name":"admin","@id":"https:\/\/www.ypmfg.com\/es\/#\/schema\/person\/1ad07d09a6f18573f3b764ab0b4a8484"},"headline":"How to Prototype a Medical Device","datePublished":"2026-11-21T02:47:52+00:00","mainEntityOfPage":{"@id":"https:\/\/www.ypmfg.com\/es\/2026\/11\/21\/how-to-prototype-a-medical-device\/"},"wordCount":908,"commentCount":0,"image":{"@id":"https:\/\/www.ypmfg.com\/es\/2026\/11\/21\/how-to-prototype-a-medical-device\/#primaryimage"},"thumbnailUrl":"https:\/\/www.ypmfg.com\/wp-content\/themes\/mb\/images_nengli\/stamping-optimized.png","keywords":["Prototyping","CNC Machining","Medical Device","Biocompatibility","Regulatory Compliance"],"articleSection":["Blog"],"inLanguage":"es","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.ypmfg.com\/es\/2026\/11\/21\/how-to-prototype-a-medical-device\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.ypmfg.com\/es\/2026\/11\/21\/how-to-prototype-a-medical-device\/","url":"https:\/\/www.ypmfg.com\/es\/2026\/11\/21\/how-to-prototype-a-medical-device\/","name":"How to Prototype a Medical Device","isPartOf":{"@id":"https:\/\/www.ypmfg.com\/es\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.ypmfg.com\/es\/2026\/11\/21\/how-to-prototype-a-medical-device\/#primaryimage"},"image":{"@id":"https:\/\/www.ypmfg.com\/es\/2026\/11\/21\/how-to-prototype-a-medical-device\/#primaryimage"},"thumbnailUrl":"https:\/\/www.ypmfg.com\/wp-content\/themes\/mb\/images_nengli\/stamping-optimized.png","datePublished":"2026-11-21T02:47:52+00:00","author":{"@id":"https:\/\/www.ypmfg.com\/es\/#\/schema\/person\/1ad07d09a6f18573f3b764ab0b4a8484"},"breadcrumb":{"@id":"https:\/\/www.ypmfg.com\/es\/2026\/11\/21\/how-to-prototype-a-medical-device\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.ypmfg.com\/es\/2026\/11\/21\/how-to-prototype-a-medical-device\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.ypmfg.com\/es\/2026\/11\/21\/how-to-prototype-a-medical-device\/#primaryimage","url":"https:\/\/www.ypmfg.com\/wp-content\/themes\/mb\/images_nengli\/stamping-optimized.png","contentUrl":"https:\/\/www.ypmfg.com\/wp-content\/themes\/mb\/images_nengli\/stamping-optimized.png","width":1536,"height":885},{"@type":"BreadcrumbList","@id":"https:\/\/www.ypmfg.com\/es\/2026\/11\/21\/how-to-prototype-a-medical-device\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.ypmfg.com\/"},{"@type":"ListItem","position":2,"name":"How to Prototype a Medical Device"}]},{"@type":"WebSite","@id":"https:\/\/www.ypmfg.com\/es\/#website","url":"https:\/\/www.ypmfg.com\/es\/","name":"YP-MFG | Piezas CNC a medida fabricadas exactamente seg\u00fan las especificaciones","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.ypmfg.com\/es\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Person","@id":"https:\/\/www.ypmfg.com\/es\/#\/schema\/person\/1ad07d09a6f18573f3b764ab0b4a8484","name":"admin","image":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/secure.gravatar.com\/avatar\/5edfa2692bdacc5e6ee805c626c50cb44cebb065f092d9a1067d89f74dacd326?s=96&d=mm&r=x","url":"https:\/\/secure.gravatar.com\/avatar\/5edfa2692bdacc5e6ee805c626c50cb44cebb065f092d9a1067d89f74dacd326?s=96&d=mm&r=x","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/5edfa2692bdacc5e6ee805c626c50cb44cebb065f092d9a1067d89f74dacd326?s=96&d=mm&r=x","caption":"admin"},"sameAs":["http:\/\/127.0.0.57"],"url":"https:\/\/www.ypmfg.com\/es\/author\/admin\/"}]}},"permalink_manager":null,"_links":{"self":[{"href":"https:\/\/www.ypmfg.com\/es\/wp-json\/wp\/v2\/posts\/1468","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ypmfg.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ypmfg.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ypmfg.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ypmfg.com\/es\/wp-json\/wp\/v2\/comments?post=1468"}],"version-history":[{"count":0,"href":"https:\/\/www.ypmfg.com\/es\/wp-json\/wp\/v2\/posts\/1468\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ypmfg.com\/es\/wp-json\/wp\/v2\/media\/1469"}],"wp:attachment":[{"href":"https:\/\/www.ypmfg.com\/es\/wp-json\/wp\/v2\/media?parent=1468"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ypmfg.com\/es\/wp-json\/wp\/v2\/categories?post=1468"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ypmfg.com\/es\/wp-json\/wp\/v2\/tags?post=1468"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}